About the use of spectrophotometer

How to use: (1) Preheat the instrument. Open the sample compartment cover (the light door closes automatically). Turn on the power, the indicator light is on, and the instrument is warmed up for 20 minutes. The selector switch is placed in the “T” knob so that the number is displayed as “00.0”. (2) Rotate the wavelength handwheel to align the desired wavelength with the tick mark. (3) Place the cuvette containing the solution in the colorimetric frame and place the reference solution on the light path. (4) Cover the sample chamber cover and adjust the light transmittance “100%T” knob so that the digital display is “100.0T”. (If the display is less than 100%T, press it once. (5) Measurement of absorbance A: After the instrument adjusts T to 0 and 100%, the selector switch is switched to the A zero knob, and the digital display should be “.000”. Then pull out the lever to place the measured solution into the optical path, and the digital display value is the absorbance A of the sample. (6) After the measurement is completed, open the sample chamber cover and then cut off the power supply. The cuvette should be cleaned. Store and store.

1. Can the spectrophotometer measure the light transmittance?

2. When is the sensitivity adjustment of the spectrophotometer used? What is the difference between him and the method of using different cuvettes?

3. Can the control in the cuvette be used all day long? Using distilled water

4, how much to put in the sample in the cuvette, I remember it seems to be 1 cm from the side of the cuvette

5. Can a spectrophotometer be able to measure the data required for two wavelengths? There is an error in adjusting the wavelength of the light source in this way. Is such data still related to the reference?

Reply

can

2. Sensitivity adjustment really needs to adjust the sensitivity when used. . . . For example, if the absorbance display is too low, the sensitivity can be adjusted to a different point. The color of the cuvette is different. According to the formula, the width can be converted proportional to the absorbance.

3. Never used it all day. . . Distilled water should be covered

4. Cuvette volume 2/3

5. Note that each measurement must be zeroed so that you can

Ethernet Slip Ring

Ethernet Slip Ring is a device that allows Ethernet signals to be transmitted through a rotating assembly. This device is typically used in applications where it is not possible or practical to run Ethernet cables, such as in an application where the cables would have to travel through a hazardous area. It converts the regular Ethernet signals into rotary signals, which are then transmitted through the rotating assembly.


There is a growing trend in the industry for Ethernet slip rings. Ethernet slip rings are currently being used to interconnect computer networks. A slip ring is a transmission device that uses a counter-rotating encircling belt to transfer power and data between two or more devices.


Senripgrid Conductive Slip Ring has the following characteristics Direct unplugging of the RJ45 connector Upon reaching eight simultaneous ports, follow the standard cable connection method Work with either copper or gas-liquor joints Transmission to the external network (10M, 100M, 1Km Base T).



Ethernet Slip Ring,Generator Collector Rings,Through Bore Rotary Union,Rotary Pressure Joint

Dongguan Oubaibo Technology Co., Ltd. , https://www.sliprobo.com