Mitsubishi plc and Mitsubishi inverter communication - Database & Sql Blog Articles

Probe high frequency needle JTK-50L-Q has 5 needles in the high frequency needle
Photocoupler

1 Mitsubishi plc: FX2N (V3.0 or higher) + FX2N-485-BD + FX2N-ROM-E1
2 Mitsubishi inverter: A500 series, E500 series, F500 series, F700 series, S500 series
FX2N-ROM-E1 is a function expansion memory, first it is 16K step EEPROM memory, and when it is used in FX2N series V3.0 or above PLC (corresponding serial number is 15**** or later) In the case of the above, you can also use the extended EXTR (FNC.180) command and Mitsubishi inverter (up to 8 units) to easily carry out 485 communication (of course, the FX2N-485-BD communication expansion board is also required).
When using the software to input the EXTR instruction, GX Developer requires SW7 or higher, and FX-PCS/WIN requires 3.10 or above.
(1) Set the D8120 (communication format) of the PLC as follows:
0000 1100 1000 0110
0 C 8 6
The corresponding meaning is: baud rate 9600bps, 7 data bits, 1 stop bit, even parity.

PCB Manufacture

In 2008,a new industrial park of Liandajin was built in Daya Bay National Economic Development Zone,huizhou with CNY120 million.The Park covers an area of 20000 square meters including 12000 square meters of manufacturing plant,The employees has been up to 1000 and the output has been 60000 square meters per month.